bdteletalk

Best Standing Pilot Gas Valve: How To Choose The Right One For Your Home

By Teletalk Desk

Standing pilot gas valves are one of the most popular types of valves used in gas appliances. They are simple and reliable, and can be used in a wide range of applications.

Why Standing Pilot Gas Valve Is Necessary?

Best standing pilot gas valve is necessary because it is the most efficient way to control the gas flow in a system. It is also the safest way to operate a gas system.

Our Top Picks For Best Standing Pilot Gas Valve

Best Standing Pilot Gas Valve Guidance

White Rodgers 36C03-333 Standing Pilot Gas Valve

White Rodgers 36C03-333 Standing Pilot Gas Valve

Check Price On Amazon

Standing pilot gas valves are designed to provide a steady supply of gas to a pilot light. They are usually used in furnaces and other appliances that use a pilot light to ignite the main burners. The White Rodgers 36C03-333 is a fast-opening gas valve with a capacity of 230,000 BTUH. It has side outlets tapped and plugged for easy installation.

Common Questions on White Rodgers 36C03-333 Standing Pilot Gas Valve

• What is the maximum inlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve?
The maximum inlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve is 1/2 psig.

• What is the minimum inlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve?
The minimum inlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve is 3.5″ w.c.

• What is the inlet gas pressure range for the White Rodgers 36C03-333 Standing Pilot Gas Valve?
The inlet gas pressure range for the White Rodgers 36C03-333 Standing Pilot Gas Valve is 3.5″ w.c. to 1/2 psig.

• What is the outlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve?
The outlet gas pressure for the White Rodgers 36C03-333 Standing Pilot Gas Valve is 3.5″ w.c.

• What is the capacity (BTU/hr) for the White Rodgers 36C03-333 Standing Pilot Gas Valve?

Why We Like This

Fast opening
BtuH capacity 230,000
Side outlets tapped and plugged
Outlet pressure regulator not required
Can be installed in any position

Additional Product Information

Color n/a
Height 4 Inches
Length 5 Inches
Weight 2.63 Pounds

Standing Pilot Gas Valve

Standing Pilot Gas Valve

Check Price On Amazon

Gas furnaces have been around for a long time. In fact, most furnaces in America are gas-fired. That’s because gas is an efficient, affordable and readily available fuel.

One of the most important components in a gas furnace is the standing pilot gas valve. This valve is responsible for supplying gas to the pilot light, which in turn ignites the burner.

The standing pilot gas valve is essentially a switch that controls the flow of gas. When the switch is turned on, gas flows to the pilot light. When the switch is turned off, the gas is shut off.

Most standing pilot gas valves are operated by a thermostat. When the thermostat calls for heat, it sends a signal to the standing pilot gas valve to turn on. This lets gas flow to the pilot light, which ignites the burner.

The standing pilot gas valve is a critical component in a gas furnace. Without it, the furnace wouldn’t be able to function.

Common Questions on Standing Pilot Gas Valve

• What is a standing pilot gas valve?

A standing pilot gas valve is a type of gas valve that uses a continuously burning pilot flame to ignite the gas when the main burner is turned on.

• How does a standing pilot gas valve work?

When the main burner is turned on, the pilot flame ignites the gas and the main burner is lit.

• What are the benefits of a standing pilot gas valve?

Standing pilot gas valves are more reliable than other types of gas valves because the pilot flame is always burning and ready to ignite the gas.

• What are the drawbacks of a standing pilot gas valve?

The main drawback of a standing pilot gas valve is that it uses a small amount of gas even when the main burner is turned off.

Why We Like This

• 1. 3/4″ 24V STANDARD OPEN
• 2. 30 300BTU W/TWO 3/4″ X 1/2″ BUSHING
• 3. HONEYWELL
• 4. Standing Pilot Gas Valve
• 5. Made in the USA

Additional Product Information

Color VR8300A4508
Height 39.3700787 Inches
Length 39.3700787 Inches
Weight 0.14 Pounds

Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve Standing Pilot, Natural Gas-

Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve Standing Pilot, Natural Gas-

Check Price On Amazon

If you’re looking to add a manual safety pilot control to your Peterson Real Fyre gas log set, then this is the product for you! The SPK-26 Standing Pilot/On/Off Valve comes with a heat shield to protect the valve from the heat of the gas log set, and it has a low profile design for use in small clearances. This product is for use with natural gas log sets only. Be sure to check the fireplace dimensions before making your purchase to ensure adequate space.

Common Questions on Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve Standing Pilot, Natural Gas-

• What is the purpose of the Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve?

The Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve is used to control the flow of natural gas to a standing pilot light.

• How does the Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve work?

The Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve works by manually opening and closing the valve to control the flow of natural gas to the pilot light.

• Why is the Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve important?

The Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve is important because it allows you to control the flow of natural gas to the pilot light, which can help prevent fires.

• How do I use the Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve?

To use the Peterson Real Fyre SPK-26 Manual On/Pilot/Off Valve, simply turn the knob to the “on” position to

Why We Like This

• Add manual safety pilot control to your Peterson Real Fyre gas log set
• Includes heat shield to protect valve from the gas log set heat
• Low profile system for use with small clearances
• Ensure adequate space in your fireplace before purchase
• For use with Natural Gas log sets

Additional Product Information

Color Natural Gas
Height 1 Inches
Length 1 Inches
Weight 1.8 Pounds

Honeywell VR8300C4506 Dual Standing Pilot Gas Valve

Honeywell VR8300C4506 Dual Standing Pilot Gas Valve

Check Price On Amazon

In today’s fast-paced world, many homeowners are looking for ways to save time and money. Honeywell’s VR8300C4506 Dual Standing Pilot Gas Valve is a great way to do both. This valve is compatible with ECO connectors and is meet codes requiring dual safety shutoff. It is also a compact size, making it ideal for smaller homes or apartments.

Common Questions on Honeywell VR8300C4506 Dual Standing Pilot Gas Valve

• What is the inlet/outlet size for this gas valve?
The inlet/outlet size for this gas valve is 3/4″.

• What is the maximum BTU capacity for this gas valve?
The maximum BTU capacity for this gas valve is 250,000 BTUs.

• What is the minimum BTU capacity for this gas valve?
The minimum BTU capacity for this gas valve is 40,000 BTUs.

• What is the turn-off capacity for this gas valve?
The turn-off capacity for this gas valve is 1/2″.

Why We Like This

1. The Honeywell VR8300C4506 Dual Standing Pilot Gas Valve is compatible with ECO connector for easy installation.
2. Its compact size makes it perfect for small spaces.
3. It meets codes requiring dual safety shutoff.
4. It has an adjustable pilot flame.
5. It is easy to operate.

Additional Product Information

Height 3.6 Inches
Length 5.8 Inches
Weight 2.45 Pounds

Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve, 5.1 ” x 3.6 ” x 4.2″

Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve, 5.1

Check Price On Amazon

A single stage, 24 Vac, standard opening gas valve, the Honeywell VR8200A2744 is a great choice for those looking for an easy to install and operate valve. Its servo pressure regulator and pilot adjustment make it a perfect fit for a variety of applications, while its compatibility with the ECO connector means it can be easily integrated into an existing system.

Common Questions on Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve, 5.1 ” x 3.6 ” x 4.2″

• What are the dimensions of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve?
The dimensions of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve are 5.1″ x 3.6″ x 4.2″.

• What is the opening of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve?
The opening of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve is standard.

• What is the standing pilot of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve?
The standing pilot of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve is a gas valve.

• What is the stage of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve?
The stage of the Honeywell VR8200A2744 Single Stage, 24 Vac, Standard Opening

Why We Like This

• 1. 24Vac Dual Standing Pilot Gas Valve
• 2. Includes manual valve, two automatic operators, servo pressure regulator, and pilot adjustment
• 3. All adjustments, wiring connections, and pilot outlet are accessible from top of control
• 4. Compatible with ECO connector
• 5. 5 3/8 in high x 4 1/16 in wide x 2 11/16 in deep

Additional Product Information

Height 5.1 Inches
Length 3.6 Inches
Weight 2.33 Pounds

Benefits of Standing Pilot Gas Valve

There are many benefits of having a best standing pilot gas valve in your home. A best standing pilot gas valve is a great way to save money on your heating costs. You will no longer have to worry about paying for propane or oil to heat your home. A best standing pilot gas valve will also help you stay warm in the winter and cool in the summer.

Buying Guide for Best Standing Pilot Gas Valve

When buying a standing pilot gas valve, there are several factors to consider in order to ensure you are getting the best possible product. Here are a few things to keep in mind:

-The first thing to consider is the brand of the valve. There are many different brands on the market, so it is important to do your research and find one that you can trust.

-It is also important to consider the type of gas that the valve will be used with. Different types of gases require different valves, so make sure you know what type of gas your appliance uses before making a purchase.

-Another thing to think about is the size of the valve. Standing pilot gas valves come in different sizes, so it is important to pick one that will fit your needs.

-Finally, make sure you read reviews before purchasing a standing pilot gas valve. This way you can get an idea of how well it works and if there have been any issues with it in the past.

Frequently Asked Question

What are the best standing pilot gas valves?

Some popular options include the Honeywell VR8200A2132 Gas Valve and the Robertshaw 720-402 Gas Valve.

What are the benefits of a standing pilot gas valve?

There are a few benefits to having a standing pilot gas valve. One is that it is less likely to get clogged than a seated pilot valve. Another is that it is less likely to leak. Finally, it is easier to repair if it does break.

What are the features of a good standing pilot gas valve?

There are several features that are important in a good standing pilot gas valve. First, it should be able to open and close quickly and smoothly. Second, it should be designed so that it does not leak gas when it is closed. Third, it should be easy to operate, with a clear indicator of when the valve is open or closed. Finally, it should be made of durable materials that can withstand repeated use.

How do I choose a standing pilot gas valve?

There are a few things to consider when choosing a standing pilot gas valve: 1. The type of gas – natural or propane2. The inlet and outlet gas pressures3. The capacity (cubic feet per hour)4. The pressure regulator setting5. The environment (outdoor or indoor) The best way to determine the best standing pilot gas valve for your application is to consult with a qualified engineer or HVAC contractor.

What are the most popular brands of standing pilot gas valves?

There are many brands of standing pilot gas valves, but the most popular are Honeywell, Williams, and White-Rodgers.

Conclusion

Give your home the best chance to withstand any potential gas leaks by outfitting it with a best standing pilot gas valve. Not only will this product save you money on your energy bills, but it will also give you peace of mind knowing that your home is as safe as possible.

Teletalk Desk

Hope you are happy to read this article. Still have you a question then feel free to ask by comment. Thank you for visiting this website.

View all posts

Top